Provide Current Location
Sign in to see your saved address

UTL

Alfa+ Solar PCU

₹ 37,789 / Number

Whatsapp
Facebook
You will earn 378 points from this product

Solar PCU Capacity2KVA 48V
Input Voltage Range (Min-Max)80-230 VDC
Maximum PV Power Recommended2KW
MPPT ControllerDSP
Type of ChargerMPPT
Efficiency95%
Battery Low BuzzerBattery Low Cut +0.2 V
Battery Low Cut10-11.7 V
Battery High Cut (INV.)SPV Present-SPV CHG. REF +1V for 15Sec, SPV CHG. REF +1.5V for 2Sec
Battery High Cut (INV.)SPV Absent-SPV CHG. REF for 15Sec, SPV CHG. REF +0.2V for 2Sec
Battery Charging Voltage by SPV13.5-16 V
Battery Charging Current by SPV12-60 A
Battery Charging Voltage by Grid13.0-15.5 V
Battery Charging Current by Grid6-15 A
Grid Low Cut Voltage (IT Mode/Normal)NA/120-200 V
Grid High Cut Voltage (IT Mode/Normal)NA/245-280 V
Grid ChargingEnable/Disable
IT LoadEnable/Disable
Operating ModeSmart/PCU/Hybrid
Output Voltage Low170-190 V
Output Voltage High250-260 V
No Load Shut DownEnable/Disable
Input SourceGrid/Genset
Grid Disconnect (Solar Available) PCU/SMART (Battery)@14.5/Battery for 2minutes or 13.5/Battery-100% Current
Grid Reconnect (PCU Mode/Smart Mode) (Battery)11-12V
Temp. Compensation (Battery)@3mV/cell/°C ; 18mV/Battery/°C
Inverter Switching ElementMosfet
Inverter ControlPWM
Inverter Nominal Output Voltage220 VAC
Inverter Output Supply Phase1Phase, 3Wire
Inverter Output WaveformPure Sine Wave
Inverter Nominal Frequency50.0 Hz
Load Current9 A
Voltage Regulation1%
Output Voltage Distortion with 100% Linear Load<3%
Peak Efficiency>88 %
CoolingTemp Controlled, Fan
ProtectionsOverload, Battery Low, Battery High, Output Low, Output High, Output Short Ckt., Overheat, Under Frequency, Over Frequency, Solar Panel Reverse
Display ParametersBattery Voltage, Charging Current, Discharging Current, Charging KWH, Discharging KWH, Solar Voltage, Solar Current, Instantaneous Power, Cumulative Power, Grid Voltage, Grid Current, Grid Frequency, Output Voltage, Output Current, Output Frequency NLSD En/Dn, IT Load En/Dn Grid Charger En/Dn, Operating Mode PCU/SMT/HYD
SwitchesReset for System ON/OFF, UP, DOWN, BACK, ENTER (for LCD Configuration)
IndicationsSystem ON, Inverter ON, SPV Charging, Grid Charging, Battery Low/High, Overload, Overheat, Mains Low, Mains High, Under Frequency, Over Frequency, NLSD, Fault
Degree of ProtectionIP21
Dimension (LxWxH)457 X 254 X 457 mm
Weight (Approx)40KG

Reviews and Ratings

StarStarStarStarStar
StarStarStarStarStar

No Customer Reviews

Share your thoughts with other customers